Cryptographic Module activation data not stored with removable hardware, v1.0

This Trustmark Definition defines conformance and assessment criteria for storing cryptographic module activation data separate from removable hardware associated with remote workstations used to administer the CA.
If an assessment step references organization-defined elements (E.g. <organization-defined personnel or roles>, <organization-defined frequency>, etc.), corresponding citations/excerpts must be provided to confirm that the organization has established and documented these values and that they apply as referenced in the conformance criteria.

Similarly, if a "Selection" among multiple options (e.g. [Selection (one or more): as needed; ]) is specified, evidence must be provided to establish that the option(s) implemented by the organization have been defined and documented.

The assessment step shall not be marked as satisfied without this evidence.

Assessment Step

1
Cryptographic Module activation data not stored with removable hardware (CryptographicModuleactivationdatanotstoredwithremovablehardware)
Is cryptographic module activation data NOT stored with the removable hardware associated with remote workstations used to administer the CA?
Artifact
A1
Provide evidence (e.g. organizational policies, procedures, compliance/assessment reports, etc.) that support the assessor's response to this assessment step.
If conformance criteria reference organization-defined elements (e.g. <organization-defined personnel or roles>, <organization-defined frequency>, etc.), these values must be defined and documented by the organization.

Similarly, if the criteria specify a "Selection" among multiple options (e.g. [Selection (one or more): as needed; ]), the option(s) implemented by the organization must also be defined and documented.

Conformance Criteria (1)

C1
Activation data shall not be stored with the removable hardware associated with remote workstations used to administer the CA.
Citation
FBCA-CP
Section 5.1.2.1